{"product_id":"myonyx-mobile-4-channel-basic-system-portable-semg-biofeedback-and-electrostimulation-hardware","title":"MyOnyx Mobile 4-Channel Basic System – Portable sEMG Biofeedback and Electrostimulation Hardware","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003ch2\u003eThought Technology MyOnyx Mobile 4-Channel Basic System: Compact Surface EMG Biofeedback and Electrostimulation Platform for Mobile Clinical Rehabilitation\u003c\/h2\u003e\n\u003cp\u003ePhysical therapy practices, outpatient rehabilitation clinics, sports medicine facilities, and pelvic health specialists require compact, highly portable neuromuscular re-education tools that deliver evidence-based biofeedback without bulky hardware tethers. The Thought Technology MyOnyx Mobile 4-Channel Basic System (Model T9020) provides an intuitive, wireless surface electromyography (sEMG) and electrical stimulation (ESTIM) solution designed to enhance patient-centered care, motor learning, and neuroplasticity across diverse clinical settings.\u003c\/p\u003e\n\u003cp\u003eThe T9020 Mobile Basic configuration is optimized for dual-mode operational control: functioning as an independent standalone device or wirelessly linked to an Android tablet via the MyOnyx Mobile App. Featuring 4 versatile input channels (Inputs A \u0026amp; B for sEMG\/ESTIM; Inputs C \u0026amp; D for ESTIM), 2048 samples\/second internal raw sEMG sampling, and state-of-the-art sEMG-Triggered Stimulation (ETS), the device rewards active patient effort with immediate functional electrical stimulation to accelerate muscle re-education and relaxation training.\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003eKey Benefits:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDual-Modality sEMG \u0026amp; Electrical Stimulation:\u003c\/b\u003e Combines 2 channels of high-speed 2048 s\/s surface EMG biofeedback with 4 channels of fully customizable electrostimulation for versatile muscular rehabilitation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWireless Android Mobile Integration:\u003c\/b\u003e Connects seamlessly via Bluetooth to Android tablets running the MyOnyx Mobile App for interactive biofeedback games, animations, and session review.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003esEMG-Triggered Stimulation (ETS):\u003c\/b\u003e Drives neuroplastic adaptation by monitoring active muscular initiation and automatically applying electrical stimulation once a set microvolt threshold is achieved.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDual Exercise ESTIM Mode:\u003c\/b\u003e Allows clinicians to run two distinct electrostimulation programs concurrently across separate channel pairs to target complex muscle groups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStandalone \"Tap \u0026amp; Go\" Operation:\u003c\/b\u003e Runs pre-programmed electrostimulation sessions directly from the handheld encoder without requiring a client selection or external PC software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e8 GB Internal Memory:\u003c\/b\u003e Archives patient session data, custom protocols, and clinical logs directly on the device for rapid access and mobile portability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMedical-Grade Portable Hardware:\u003c\/b\u003e Includes a rechargeable internal battery, patient drive lead for shared ground, and safety-certified power supply for clinical environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eChannel Inputs:\u003c\/b\u003e 4 total inputs (Inputs A \u0026amp; B: sEMG or ESTIM; Inputs C \u0026amp; D: ESTIM only)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003esEMG Sampling Rate:\u003c\/b\u003e Internal raw signal sampling at 2048 samples\/second\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSignal Display:\u003c\/b\u003e Root Mean Square (RMS) signal processing displayed within the MyOnyx Android App\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperational Modes:\u003c\/b\u003e Standalone mode and Bluetooth Remote Control mode via Android tablet\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInternal Storage:\u003c\/b\u003e 8 GB internal memory for protocol storage and offline session logging\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWireless Connectivity:\u003c\/b\u003e High-speed Bluetooth wireless connection to Android tablets\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIncluded Software:\u003c\/b\u003e MyOnyx Mobile App (available via Google Play Store)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIncluded Accessories:\u003c\/b\u003e 1 MyOnyx device, 4 EMG\/STIM 2-lead cables with DIN connectors, 1 patient drive lead, medical-grade power supply, 4 DIN-to-snap adapters, electrode samples (3 Unigel \u0026amp; 1 AxelGaard STIM), and hardware manual\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRegulatory Compliance:\u003c\/b\u003e USA Federal law restricts this device to sale by or on the order of a licensed healthcare practitioner\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCommercial Warranty:\u003c\/b\u003e Manufacturer standard commercial\/clinical warranty coverage included\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fabrication Enterprises","offers":[{"title":"Default Title","offer_id":67816646181108,"sku":"FEI-13-1446","price":2750.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2304\/8155\/files\/MyOnyx__19350_673d7e74-7037-4650-b4c4-f44832280aa0.webp?v=1793072151","url":"https:\/\/rescue-supply.com\/products\/myonyx-mobile-4-channel-basic-system-portable-semg-biofeedback-and-electrostimulation-hardware","provider":"Rescue Supply","version":"1.0","type":"link"}