Phillips Safety Ceiling-Mounted Lead Acrylic Barrier with Torso Cutout, LED Exam Light, and 0.5mm PbEq Shielding
- Brand: Phillips Safety
- Availability: Factory Direct
- Fulfillment: Ships 2-4 Weeks!
We are authorized retailers for all brands we carry. Warranty details are listed on each product page.
Some manufacturers require registration or activation shortly after deliveryāplease check the product page or visit the brand's website for specifics.
Note: Warranties do not cover shipping damage. Please inspect your shipment upon arrival and note any issues on the Bill of Lading. Refuse delivery if damage is severe.
Questions? Contact Rescue Supply for support.
At Rescue Supply, weāre committed to providing exceptional value, quality, and selectionābecause your satisfaction matters. If for any reason youāre not completely happy with your purchase, most unused items may be returned for a refund or exchange within 30 days of the original purchase date, excluding items listed under our exceptions and exclusions.
Phillips Safety Ceiling-Mounted Radiation Shield: Anatomical Torso Cutout with Integrated LED Illumination
The Phillips Safety Ceiling-Mounted Lead Acrylic Barrier is an advanced radiation safety system engineered specifically for high-acuity environments such as interventional cardiology, radiology, and hybrid operating rooms. This multi-functional unit provides a certified 0.5mm PbEq attenuation zone, utilizing high-clarity lead acrylic to shield clinicians from scatter radiation without compromising visibility. The specialized anatomical torso cutout allows the barrier to be positioned in close proximity to the patient, maximizing the protective shadow for the practitioner while maintaining an unobstructed surgical field.
Designed for institutional efficiency, this system integrates a professional-grade LED exam light directly into the articulated shielding assembly. This dual-capability eliminates the need for redundant ceiling mounts, reducing equipment clutter and streamlining clinical workflows. The counterbalanced suspension system ensures effortless maneuverability, allowing clinicians to rapidly adjust the shield and lighting with one hand. Built to withstand the rigorous demands of hospital environments, this ceiling-suspended solution improves safety and ergonomics by removing floor-based obstacles and trip hazards.
Key Benefits:
- Anatomical Torso Cutout: Contoured shield design facilitates closer positioning to the patient, significantly increasing the effective area of radiation protection.
- Integrated LED Exam Light: Provides high-intensity, cool-temperature task lighting centered directly within the clinical workspace.
- High-Efficiency Attenuation: Delivers 0.5mm lead equivalent (PbEq) protection to mitigate occupational dose from secondary scatter radiation.
- Superior Optical Clarity: Transparent lead acrylic pane ensures a distortion-free view of the procedural site and vital monitors.
- Flexible Lead Curtain: Features a secondary 0.5mm PbEq lead drape to provide extended shielding for the clinician's midsection and lower torso.
- Articulated Suspension: The counterbalanced internal spring arm offers 360-degree rotation and fluid vertical/horizontal positioning.
- Space-Saving Ceiling Mount: Optimizes surgical suite floor space and reduces the risk of equipment collisions during complex procedures.
Specifications:
- Radiation Protection: 0.5mm PbEq Lead Acrylic and 0.5mm PbEq Lead Curtain
- Shield Dimensions: 60cm x 76cm (approx. 24" x 30") with Torso Cutout
- Light Source: Integrated LED Exam Light with adjustable positioning
- Mounting: Ceiling-mounted stationary track or fixed-point system
- Material: Medical-grade transparent lead acrylic and lead-impregnated vinyl
- Movement: Fully articulated, counterbalanced suspension arm
- Application: Interventional Cardiology, Radiology, Orthopedic Surgery, and Hybrid ORs
Phillips Safety Comparison: Ceiling-Mounted Systems
| Feature | Shield w/ Light | Torso Shield (Basic) | Standard Shield | Torso Shield w/ Light |
|---|---|---|---|---|
| SKU | PTO-005 | PTO-006 | PTO-007 | PTO-008 |
| Primary Use | Protection & Task Lighting | Max Proximity Protection | Secondary Scatter Protection | Proximity Shielding & Light |
| Integrated Light | LED Exam Light | No | No | LED Exam Light |
| Lead Equivalence | 0.5mm PbEq | 0.5mm PbEq | 0.5mm PbEq | 0.5mm PbEq |
| Material | Lead Acrylic & Alloy | Lead Acrylic & Alloy | Lead Acrylic & Alloy | Lead Acrylic & Alloy |
| Dimensions | 60cm x 76cm | 60cm x 76cm | 60cm x 76cm | 60cm x 76cm |
| Action | View w/ Light | View Torso Basic | View Standard | View Torso w/ Light |
Why Buy From Rescue-Supply.com?
We know you have a choice for your rescue supply needs but we want to do all that we can do to earn your business. We not only want to earn it but we want to keep it as well!Ā If you have any questions or concerns about any product on our store or the service we provide please don't hesitate to contact us today!
- Toll Free Customer Service Number: (800) 239-1797
- Email Order Contact: orders@rescue-supply.com
Here are the Top 6 Reasons to Buy from Rescue-Supply.com:
100% SAFE & SECURE ONLINE SHOPPING:
Know that every transaction that takes place on our website is 100% secure. If you'd like to learn more, see our Online Security page.
FULLY INSURED SHIPMENTS:
Every shipment that leaves our warehouses is fully covered in case of a loss or damage. Please refer to the Shipping & ReturnsĀ page to learn more about our policy.
WE ONLY SELL QUALITY PRODUCTS:
We understand what it can be like to purchase products online without actually seeing and touching the product itself. We want you to know that every manufacturers that we work with are hand chosen by our owners to ensure you receive a quality product. All items leaving our warehouse are quality checked twice before leaving our warehouses across the country to ensure you're 100% be happy with the product that arrives at your door.
CUSTOMER SERVICE IS PRIORITY #1:
Your satisfaction is our highest priority 100% of the time. Our mission is to provide excellent customer service before and after the order and our goal is to become your primary source for all of your rescue supply needs. You can expect communication from us immediately after your order is placed and when your product ships. To this day, every order still receives an email from our owner personally thanking you for letting us earn your business.
WE ARE AUTHORIZED DEALERS:
Rescue-Supply.com is an authorized dealer for every brand that we carry. You can rest easy knowing you will receive the full manufacturer's warranty with every purchase.
LOOKING FOR VOLUME DISCOUNTS?:
Interested in purchasing in bulk and want to inquire about volume discounts? Send us an email at info@Rescue-Supply.com and we may be able to offer special pricing to suit your needs!
Your Information is Secure with Us!
Every transaction at Rescue-Supply.com is guaranteed to be safe and most importantly secure.
This site uses SSL encryption technology that so that you never have to worry about credit card safety.
Statistically speaking, online purchases are much safer than using your credit card at a department store or a gas station. Experts have shown that online purchases are far safer than in person credit card transactions because the information is immediately encrypted into a 128 bit, highly scrambled message that can only be decrypted by our authorized payment processors.
Still donāt want to use your credit card on the World Wide Web?Ā Weāve got you covered! Simply call one of our friendly customer service representatives at (800) 239-1797 and we will gladly help you place your order.
Product Specifications
Frequently Asked Questions
Find answers to commonly asked questions below.
-
Does this ceiling-mounted barrier meet the 0.5mm PbEq shielding standards required for high-dose interventional radiology?
The Phillips Safety PTO-008 provides a certified 0.5mm PbEq (lead equivalence) protection level, which is the industry standard for secondary radiation attenuation in interventional suites. This specific rating ensures that scatter radiation is effectively blocked, protecting the head and upper torso of the clinician during fluoroscopic procedures. By utilizing high-density lead acrylic, the barrier achieves this safety benchmark while maintaining the optical clarity necessary for precision medical work. This certification is essential for facilities aiming to stay compliant with ALARA safety mandates and state-specific radiation health regulations. The uniform 0.5mm PbEq shielding offers a reliable safety margin for table-side staff during high-frequency diagnostic imaging.
-
How does the integration of a medical LED light into the radiation shield improve workflow and space management in the OR?
Integrating a high-intensity LED light directly into the radiation shield allows for the simultaneous adjustment of illumination and protection, streamlining the entire surgical workflow. By consolidating these two essential tools into a single ceiling-mounted column, facility managers can significantly reduce the "clutter" of multiple articulating arms in the surgical field. The LED light is engineered for high color rendering, ensuring that the clinician has a daylight-accurate view through the lead acrylic window. This dual-purpose design improves room efficiency by providing localized lighting exactly where the operator is looking through the protective pane. Reducing the number of separate overhead units also lowers the risk of mechanical collisions between different pieces of suspended medical equipment.
-
What are the specific dimensions of the lead acrylic window and how does the torso cutout improve operator safety?
The lead acrylic window measures 32ā x 24ā and features a specialized anatomical torso cutout that allows the shield to be positioned closer to the patient and the imaging equipment. This cutout is a critical safety feature because it minimizes the gaps through which scatter radiation can escape, providing superior coverage compared to flat-edged barriers. By fitting the shield securely around the procedural site, the operator can maintain a natural working posture while remaining within the "protected shadow" of the lead acrylic. The expansive 32ā width provides ample lateral shielding for the operator, ensuring that the upper body remains fully attenuated. This anatomical design is particularly effective in interventional cardiology and radiology where close patient proximity is required.
-
What design features are included to ensure mechanical stability and prevent the articulating arm from drifting over time?
This unit features a precision-engineered stabilized suspension arm with adjustable friction joints to prevent the common issue of arm drift during procedures. The internal spring-balanced mechanism ensures that the 0.5mm PbEq barrier stays exactly where the operator positions it, even during extended surgical sessions. The high-quality powder-coated alloy construction is designed to withstand the corrosive effects of hospital-grade disinfectants without surface degradation. By focusing on mechanical reliability, the system offers a lower total cost of ownership by reducing the frequency of maintenance and recalibration. This robust build quality ensures the unit remains a dependable safety asset in high-throughput environments for the duration of its service life.
-
What are the structural requirements for mounting this 360-degree rotating system to a hospital ceiling grid?
The Phillips Safety PTO-008 requires a secure attachment to the structural ceiling slab or a reinforced support grid capable of handling the unit's weight and articulating torque. Facility managers must ensure the stationary column is positioned to allow the full 360-degree rotation to clear other overhead modalities like monitor booms or anesthesia tracks. We recommend a professional structural assessment prior to installation to verify that the mounting plate is properly fastened to the building's infrastructure. Proper installation ensures that the arm remains plumb and moves with minimal physical effort from the medical staff throughout the day. Because this is a ceiling-mounted system, it provides a superior floor-space solution for interventional suites where mobile bases could cause a trip hazard or obstruction.