B. Braun Introcan IV Catheter 20G x 1 1/4" — Winged Peripheral Venous Access
- Brand: Jorgensen Labs
- Availability: Factory Direct
- Fulfillment: Ships 2-3 Days!
We are authorized retailers for all brands we carry. Warranty details are listed on each product page.
Some manufacturers require registration or activation shortly after delivery—please check the product page or visit the brand's website for specifics.
Note: Warranties do not cover shipping damage. Please inspect your shipment upon arrival and note any issues on the Bill of Lading. Refuse delivery if damage is severe.
Questions? Contact Rescue Supply for support.
At Rescue Supply, we’re committed to providing exceptional value, quality, and selection—because your satisfaction matters. If for any reason you’re not completely happy with your purchase, most unused items may be returned for a refund or exchange within 30 days of the original purchase date, excluding items listed under our exceptions and exclusions.
B. Braun Introcan IV Catheter 20G x 1 1/4" Winged: Peripheral Venous Access for Clinical and Veterinary Care
The B. Braun Introcan IV Catheter in the 20G x 1 1/4" winged configuration is a peripheral venous access device used to deliver fluids, medications, and blood products through a peripheral vein. The winged hub design gives the clinician a stable platform for insertion and for securing the catheter against the skin once placed, which helps limit catheter movement during infusion therapy.
Jorgensen Laboratories supplies this B. Braun catheter to veterinary and clinical practices as model J1431C. The 20-gauge size is a general-purpose choice for routine fluid and medication administration, and the catheter is supplied sterile for single use.
Key Benefits:
- Winged Hub: Integrated wings provide a secure grip during insertion and a broad base for taping or suturing the catheter in place.
- FEP Catheter Material: The Introcan line uses FEP polymer catheter material, the standard B. Braun catheter construction for this product family.
- General-Purpose 20G Size: The 20-gauge bore supports routine fluid and medication delivery in general clinical and veterinary practice.
- Pink Color Coding: The pink hub follows the standard gauge color code, allowing fast size identification at the point of care.
- Sterile Single Use: Supplied sterile and intended for one-time use to support infection-control practice.
Specifications:
- Manufacturer: B. Braun
- Model: Introcan, winged (Jorgensen Laboratories J1431C)
- Gauge: 20G
- Catheter Length: 1 1/4 in. (32 mm)
- Material: FEP polymer
- Hub Type: Winged
- Color Code: Pink
- Sterility: Sterile, single use
Why Buy From Rescue-Supply.com?
We know you have a choice for your rescue supply needs but we want to do all that we can do to earn your business. We not only want to earn it but we want to keep it as well! If you have any questions or concerns about any product on our store or the service we provide please don't hesitate to contact us today!
- Toll Free Customer Service Number: (800) 239-1797
- Email Order Contact: orders@rescue-supply.com
Here are the Top 6 Reasons to Buy from Rescue-Supply.com:
100% SAFE & SECURE ONLINE SHOPPING:
Know that every transaction that takes place on our website is 100% secure. If you'd like to learn more, see our Online Security page.
FULLY INSURED SHIPMENTS:
Every shipment that leaves our warehouses is fully covered in case of a loss or damage. Please refer to the Shipping & Returns page to learn more about our policy.
WE ONLY SELL QUALITY PRODUCTS:
We understand what it can be like to purchase products online without actually seeing and touching the product itself. We want you to know that every manufacturers that we work with are hand chosen by our owners to ensure you receive a quality product. All items leaving our warehouse are quality checked twice before leaving our warehouses across the country to ensure you're 100% be happy with the product that arrives at your door.
CUSTOMER SERVICE IS PRIORITY #1:
Your satisfaction is our highest priority 100% of the time. Our mission is to provide excellent customer service before and after the order and our goal is to become your primary source for all of your rescue supply needs. You can expect communication from us immediately after your order is placed and when your product ships. To this day, every order still receives an email from our owner personally thanking you for letting us earn your business.
WE ARE AUTHORIZED DEALERS:
Rescue-Supply.com is an authorized dealer for every brand that we carry. You can rest easy knowing you will receive the full manufacturer's warranty with every purchase.
LOOKING FOR VOLUME DISCOUNTS?:
Interested in purchasing in bulk and want to inquire about volume discounts? Send us an email at info@Rescue-Supply.com and we may be able to offer special pricing to suit your needs!
Your Information is Secure with Us!
Every transaction at Rescue-Supply.com is guaranteed to be safe and most importantly secure.
This site uses SSL encryption technology that so that you never have to worry about credit card safety.
Statistically speaking, online purchases are much safer than using your credit card at a department store or a gas station. Experts have shown that online purchases are far safer than in person credit card transactions because the information is immediately encrypted into a 128 bit, highly scrambled message that can only be decrypted by our authorized payment processors.
Still don’t want to use your credit card on the World Wide Web? We’ve got you covered! Simply call one of our friendly customer service representatives at (800) 239-1797 and we will gladly help you place your order.
Product Specifications
Frequently Asked Questions
Find answers to commonly asked questions below.
-
How does the 20G x 1 1/4" B. Braun Introcan's Double Flashback technology enhance first-stick success during high-volume fluid resuscitation?
The B. Braun Introcan utilizes proprietary Double Flashback technology to provide separate, immediate visual confirmation of both needle entry and successful catheter placement within the vessel. Upon initial venipuncture, a primary flashback appears in the needle chamber to confirm the tip has entered the lumen, followed by a secondary flashback between the catheter and the needle to signal successful cannula advancement. This dual-indicator system is critical for technical specialists performing rapid vascular access, as it minimizes the risk of through-and-through punctures. By ensuring the catheter is correctly positioned before the needle is withdrawn, the device significantly increases first-stick success rates in high-pressure clinical environments. This level of visual precision is a benchmark for advanced peripheral venous access in both human and veterinary medicine.
-
What specific passive safety features of the Introcan IV Catheter ensure institutional compliance with OSHA Bloodborne Pathogens standards?
This IV catheter incorporates a fully automatic passive safety shield that permanently encases the needle tip upon withdrawal without requiring any secondary activation steps from the operator. Unlike active safety systems that rely on a manual button or slide, this passive mechanism cannot be bypassed, ensuring 100% compliance with sharps-safety mandates and OSHA Bloodborne Pathogens standards. The safety clip deploys instantly as the needle is retracted from the catheter hub, effectively eliminating the risk of accidental needle-stick injuries (NSIs) during disposal. This "no-step" protection design is proven to be significantly more effective than active systems at reducing exposure to bloodborne pathogens in high-stress surgical suites. Standardizing on passive safety technology protects institutional staff while streamlining the hazardous waste disposal process.
-
How do the material properties of the pink-coded polyurethane (PUR) cannula improve patient comfort and extend dwell-time?
The 20G Introcan is manufactured from medical-grade polyurethane (PUR), a high-performance thermoplastic that remains rigid for easy insertion but softens significantly at body temperature. Once indwelling, the cannula becomes flexible and conforms to the vascular anatomy, which drastically reduces mechanical phlebitis and vessel wall irritation. This material advantage, combined with a thin-wall design, allows for a high flow rate of approximately 60 mL/min, which is ideal for rapid fluid administration. Polyurethane also offers superior kink-resistance compared to traditional FEP materials, ensuring consistent delivery of intravenous fluids even in active patients. These technical specifications directly contribute to longer viable dwell-times and a more comfortable experience for the patient.
-
Is the B. Braun Introcan 20G Catheter rated for power injection of contrast media in diagnostic imaging?
This 20-gauge pink Introcan catheter is pressure-rated for contrast media applications up to 300 psi when used with automated power injectors. This high-pressure tolerance makes it an exceptionally versatile tool, suitable for both standard infusion therapy and specialized radiological procedures in the ICU or ER. The robust polyurethane construction prevents catheter rupture or deformation under the significant hydraulic forces required for modern diagnostic imaging protocols. Technical specialists can rely on this standardized hardware for diverse clinical needs, from routine maintenance fluids to high-velocity CT scan injections. Having a 300 psi rating on a standard peripheral catheter simplifies inventory requirements and ensures the device can handle the mechanical stresses of automated delivery.
-
What are the TCO and ROI advantages of standardizing on B. Braun Introcan passive safety catheters for large-scale clinical facilities?
Standardizing on B. Braun Introcan passive safety catheters provides a superior TCO by reducing the incidence of needle-stick injuries and the associated high costs of post-exposure prophylaxis and liability. While the initial unit cost may be higher than non-safety alternatives, the superior dwell-time of the polyurethane cannula results in fewer restarts and reduced consumable waste. Facilities experience lower labor costs as technical specialists spend less time managing catheter failures and mechanical phlebitis complications. The reduction in "nuisance" dislodgements due to the stable winged hub design further improves the overall return on investment. Over a fiscal cycle, the increased reliability and enhanced professional safety lead to measurable savings in both clinical time and administrative overhead.
